ISU
Installer Setup
Number
Name
9130
Dehumidifier Fan
Control
9140
Dehumidifier
Lockout
9180
Dehumidification
Away Mode
9190
Dehumidification
Away Mode - Fan
Control
9200
Dehumidification
Away Mode - Low
Limit Temperature
Setting
9200
Dehumidification
Away Mode -
Temperature
Setting
9200
Dehumidification
Away Mode -
Dehumidification
Setting
9210
Dehumidifier Filter
Replacement
Reminder
Table 4. Installer Setup (ISU) Table. (Continued)
Settings
Thermostat Controls Fan
Equipment Controls Fan
Dehumidifier Allowed when Cool
is Running
Dehumidifier Not Allowed when
Cool is Running
Not Allowed
Allowed
Automatic
On
Circulate
70° F to 80° F
70° F to 99° F
40% to 70% (in 5% increments)
Off
30, 60, Calendar Days
3 to 12 Calendar Months (in 1
month increments)
®
THX9321 PRESTIGE
2.0 AND THX9421 PRESTIGE
Residential,
Commercial
Default
or Both
Thermostat
Both
Controls Fan
Dehumidifier
Both
Allowed when
Cool is
Running
Not Allowed
Both
Automatic
Both
76° F
Both
85° F
Both
65%
Both
Off
Both
59
Requires
EIM
Notes
No
This ISU is only displayed when ISU 9000
Dehumidification Equipment is set to
Dehumidifier.
Thermostat Controls Fan: The thermostat
turns on the dehumidifier and the fan when
dehumidification is needed.
Equipment Controls Fan: The thermostat
turns on the dehumidifier when
dehumidification is needed. The fan is
controlled by the equipment.
No
This ISU is only displayed when ISU 9000
Dehumidification Equipment is set to
Dehumidifier.
Dehumidifier Allowed when Cool is
Running: Dehumidifier can run when the
cooling system is on.
Dehumidifier Not Allowed when Cool is
Running: Dehumidifier can NOT run when
the cooling system is on.
No
This ISU is NOT displayed when ISU 9000
Dehumidification Equipment is None.
ISU 9190 to 9200 are only displayed when
ISU 9180 Dehumidification Away Mode is
Allowed.
See "Dehumidification Away Mode"
beginning on page 107.
No
The On and Circulate settings may re-
introduce humidity into the living space.
No
If the cooling system is used to control
humidity while Dehumidification Away
Mode is active, the thermostat allows the
cooling system to lower the indoor air to
the Low Limit Temperature Setting to reach
the dehumidification setting at ISU 9200.
No
The temperature maintained while
Dehumidification Away Mode is active and
the desired humidity level is satisfied.
No
The desired humidity level while
Dehumidification Away Mode is active.
No
®
IAQ WITH EIM
68-0311—02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thx9421 prestige iaq with eim

Table of Contents