THX9321 PRESTIGE
2.0 AND THX9421 PRESTIGE

INSTALLER TESTS

Use the installer tests to check out the system:
• Equipment Test: Tests the heating, cooling, fan, and IAQ
equipment. The test allows you to manually call for each
system to ensure the equipment and thermostat operate
properly. Any minimum off timers are ignored during the
system test. You can test the following equipment:
— Heat
— Em Heat
— Cool
— Fan
— Humidification
— Dehumidification
— Ventilation
— Economizer
— Time of Day
• Wireless Signal Strength Test: Run this test to verify that
the thermostat can communicate properly in the installed
location. The test measures the signal strength between the
— Thermostat and the Equipment Interface Module (in
non-zoned applications)
— Thermostat and the TrueZONE Wireless Adapter (in
zoned applications)
68-0311—02
®
IAQ WITH EIM

Accessing Installer Tests

1. Press MENU on the home screen, then scroll down and
press Installer Options.
2. Enter the password (date code) when prompted. See
"Finding Your Password (Date Code) to Access Installer
Options" beginning on page 20.
3. Press Installer Test.
4. Select Equipment Test or Wireless Signal Strength Test.
CAUTION
Equipment Damage Hazard.
Minimum compressor off time is bypassed during
the Equipment Test
Avoid cycling compressor quickly.