GE C70 Instruction Manual page 524

Capacitor bank protection and control system
Hide thumbs Also See for C70:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 21 of 61)
ADDR
REGISTER NAME
4341
...Repeated for User-Programmable LED 44
4344
...Repeated for User-Programmable LED 45
4347
...Repeated for User-Programmable LED 46
434A
...Repeated for User-Programmable LED 47
434D
...Repeated for User-Programmable LED 48
PRP Status (Read Only)
4363
Total Received Port A
4365
Total Received Port B
4367
Total Mismatches Port A
4369
Total Mismatches Port B
B
436B
Total Errors
IPv4 Route Table (Read/Write Setting) (6 Modules)
4370
IPv4 Network Route 1 Destination
4372
IPv4 Network Route 1 Netmask
4374
IPv4 Network Route 1 Gateway
4376
...Repeated for Route 2
437C
...Repeated for Route 3
4382
...Repeated for Route 4
4388
...Repeated for Route 5
438E
...Repeated for Route 6
Installation (Read/Write Setting)
43E0
Relay Programmed State
43E1
Relay Name
User Programmable Self Tests (Read/Write Setting)
4441
User Programmable Detect Ring Break Function
4442
User Programmable Direct Device Off Function
4443
User Programmable Remote Device Off Function
4444
User Programmable First Ethernet Fail Function
4445
User Programmable Secondary Ethernet Fail Function
4446
User Programmable Battery Fail Function
4447
User Programmable SNTP Fail Function
4448
User Programmable IRIG-B Fail Function
444A
Process Bus Failure Operand
444C
PTP Fail Function
444D
User Programmable Third Ethernet Fail Function
444E
User Programmable SFP Fail Function
CT Settings (Read/Write Setting) (6 modules)
4480
Phase CT 1 Primary
4481
Phase CT 1 Secondary
4482
Ground CT 1 Primary
4483
Ground CT 1 Secondary
4484
...Repeated for CT Bank 2
4488
...Repeated for CT Bank 3
448C
...Repeated for CT Bank 4
4490
...Repeated for CT Bank 5
4494
...Repeated for CT Bank 6
VT Settings (Read/Write Setting) (3 modules)
4500
Phase VT 1 Connection
4501
Phase VT 1 Secondary
4502
Phase VT 1 Ratio
4504
Auxiliary VT 1 Connection
4505
Auxiliary VT 1 Secondary
4506
Auxiliary VT 1 Ratio
B-28
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
1 to 65000
1 to 65000
25 to 240
1 to 24000
25 to 240
1 to 24000
C70 Capacitor Bank Protection and Control System
RANGE
UNITS
STEP
---
1
---
1
---
1
---
1
---
1
---
1
---
1
---
1
0 to 1
---
1
---
---
---
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
A
1
0 to 1
---
1
A
1
0 to 1
---
1
0 to 1
---
1
V
0.1
:1
1
0 to 6
---
1
V
0.1
:1
1
APPENDIX B
FORMAT
DEFAULT
F003
0
F003
0
F003
0
F003
0
F003
0
F003
2130706433
F003
4294966272
F003
2130706433
F133
0 (Not
Programmed)
F202
"Relay-1"
F102
1 (Enabled)
F102
1 (Enabled)
F102
1 (Enabled)
F102
0 (Disabled)
F102
0 (Disabled)
F102
1 (Enabled)
F102
1 (Enabled)
F102
1 (Enabled)
F300
0
F102
1 (Enabled)
F102
0 (Disabled)
F102
0 (Disabled)
F001
1
F123
0 (1 A)
F001
1
F123
0 (1 A)
F100
0 (Wye)
F001
664
F060
1
F166
1 (Vag)
F001
664
F060
1
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents