GE C70 Instruction Manual page 242

Capacitor bank protection and control system
Hide thumbs Also See for C70:
Table of Contents

Advertisement

5.5 FLEXLOGIC
Table 5–12: C70 FLEXLOGIC OPERANDS (Sheet 7 of 9)
OPERAND TYPE
OPERAND SYNTAX
ELEMENT:
VOLT DIF 1 STG1A PKP
Voltage differential
VOLT DIF 1 STG1B PKP
VOLT DIF 1 STG1C PKP
VOLT DIF 1 STG2A PKP
VOLT DIF 1 STG2B PKP
VOLT DIF 1 STG2C PKP
VOLT DIF 1 STG3A PKP
VOLT DIF 1 STG3B PKP
VOLT DIF 1 STG3C PKP
VOLT DIF 1 STG4A PKP
VOLT DIF 1 STG4B PKP
VOLT DIF 1 STG4C PKP
VOLT DIF 1 PKP A
VOLT DIF 1 PKP B
VOLT DIF 1 PKP C
VOLT DIF 1 PKP
VOLT DIF 1 DPO
VOLT DIF 1 STG1A OP
VOLT DIF 1 STG1B OP
VOLT DIF 1 STG1C OP
VOLT DIF 1 STG2A OP
VOLT DIF 1 STG2B OP
VOLT DIF 1 STG2C OP
VOLT DIF 1 STG3A OP
VOLT DIF 1 STG3B OP
VOLT DIF 1 STG3C OP
VOLT DIF 1 STG4A OP
VOLT DIF 1 STG4B OP
VOLT DIF 1 STG4C OP
VOLT DIF 1 OP A
VOLT DIF 1 OP B
5
VOLT DIF 1 OP C
VOLT DIF 1 OP
VOLT DIF 2 to 3
FIXED OPERANDS
Off
On
INPUTS/OUTPUTS:
Cont Ip 1
Contact inputs
Cont Ip 2
Cont Ip 1
Cont Ip 2
INPUTS/OUTPUTS:
Cont Op 1
Contact outputs,
Cont Op 2
current
(from detector on
form-A output only)
INPUTS/OUTPUTS:
Cont Op 1
Contact outputs,
Cont Op 2
voltage
(from detector on
Cont Op 1
form-A output only)
Cont Op 2
INPUTS/OUTPUTS
DIRECT INPUT 1 On
Direct inputs
DIRECT INPUT 32 On
INPUTS/OUTPUTS:
RemDPS Ip 1 BAD
Remote double-
RemDPS Ip 1 INTERM
point status inputs
RemDPS Ip 1 OFF
RemDPS Ip 1 ON
REMDPS Ip 2...
INPUTS/OUTPUTS:
REMOTE INPUT 1 On
Remote inputs
REMOTE INPUT 2 On
REMOTE INPUT 2 On
REMOTE INPUT 32 On
5-118
OPERAND DESCRIPTION
Voltage differential element 1 picked up in phase A of stage 1
Voltage differential element 1 picked up in phase B of stage 1
Voltage differential element 1 picked up in phase C of stage 1
Voltage differential element 1 picked up in phase A of stage 2
Voltage differential element 1 picked up in phase B of stage 2
Voltage differential element 1 picked up in phase C of stage 2
Voltage differential element 1 picked up in phase A of stage 3
Voltage differential element 1 picked up in phase B of stage 3
Voltage differential element 1 picked up in phase C of stage 3
Voltage differential element 1 picked up in phase A of stage 4
Voltage differential element 1 picked up in phase B of stage 4
Voltage differential element 1 picked up in phase C of stage 4
Voltage differential element 1 picked up in phase A
Voltage differential element 1 picked up in phase B
Voltage differential element 1 picked up in phase C
Voltage differential element 1 picked up
Voltage differential element 1 dropped out
Voltage differential element 1 operated in phase A of stage 1
Voltage differential element 1 operated in phase B of stage 1
Voltage differential element 1 operated in phase C of stage 1
Voltage differential element 1 operated in phase A of stage 2
Voltage differential element 1 operated in phase B of stage 2
Voltage differential element 1 operated in phase C of stage 2
Voltage differential element 1 operated in phase A of stage 3
Voltage differential element 1 operated in phase B of stage 3
Voltage differential element 1 operated in phase C of stage 3
Voltage differential element 1 operated in phase A of stage 4
Voltage differential element 1 operated in phase B of stage 4
Voltage differential element 1 operated in phase C of stage 4
Voltage differential element 1 operated in phase A
Voltage differential element 1 operated in phase B
Voltage differential element 1 operated in phase C
Voltage differential element 1 operated
Same set of operands as shown for VOLT DIF 1 above
Logic = 0. Does nothing and may be used as a delimiter in an equation list;
used as 'Disable' by other features.
Logic = 1. Can be used as a test setting.
On
(will not appear unless ordered)
On
(will not appear unless ordered)
Off
(will not appear unless ordered)
Off
(will not appear unless ordered)
IOn
(will not appear unless ordered)
IOn
(will not appear unless ordered)
VOn
(will not appear unless ordered)
VOn
(will not appear unless ordered)
VOff
(will not appear unless ordered)
VOff
(will not appear unless ordered)
Flag is set, logic=1
Flag is set, logic=1
Asserted while the remote double-point status input is in the bad state.
Asserted while the remote double-point status input is in the intermediate
state.
Asserted while the remote double-point status input is off.
Asserted while the remote double-point status input is on.
Same set of operands as per REMDPS 1 above
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
C70 Capacitor Bank Protection and Control System