GE C70 Instruction Manual page 510

Capacitor bank protection and control system
Hide thumbs Also See for C70:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 7 of 61)
ADDR
REGISTER NAME
21A8
Breaker flashover 1 supervision phase C
21AA
Breaker flashover 1 block
21AC
Breaker flashover 1 events
21AD
Breaker flashover 1 target
21AE
Reserved (4 items)
21B2
...Repeated for breaker flashover 2
Passwords Unauthorized Access (Read/Write Command)
2230
Reset Unauthorized Access
Field Unit Raw Data Settings (Read/Write Setting)
2460
Field Raw Data Port
B
2461
Field Raw Data Freeze
Remote double-point status inputs (read/write setting registers) (5 modules)
2620
Remote double-point status input 1 device
2621
Remote double-point status input 1 item
2622
Remote double-point status input 1 name
2628
Remote double-point status input 1 events
2629
... Repeated for double-point status input 2
2632
... Repeated for double-point status input 3
263B
... Repeated for double-point status input 4
2644
... Repeated for double-point status input 5
IEC 61850 GGIO5 configuration (read/write setting registers) (16 modules)
26B0
IEC 61850 GGIO5 uinteger input 1 operand
26B1
IEC 61850 GGIO5 uinteger input 2 operand
26B2
IEC 61850 GGIO5 uinteger input 3 operand
26B3
IEC 61850 GGIO5 uinteger input 4 operand
26B4
IEC 61850 GGIO5 uinteger input 5 operand
26B5
IEC 61850 GGIO5 uinteger input 6 operand
26B6
IEC 61850 GGIO5 uinteger input 7 operand
26B7
IEC 61850 GGIO5 uinteger input 8 operand
26B8
IEC 61850 GGIO5 uinteger input 9 operand
26B9
IEC 61850 GGIO5 uinteger input 10 operand
26BA
IEC 61850 GGIO5 uinteger input 11 operand
26BB
IEC 61850 GGIO5 uinteger input 12 operand
26BC
IEC 61850 GGIO5 uinteger input 13 operand
26BD
IEC 61850 GGIO5 uinteger input 14 operand
26BE
IEC 61850 GGIO5 uinteger input 15 operand
26BF
IEC 61850 GGIO5 uinteger input 16 operand
IEC 61850 received integers (read only actual values)
26F0
IEC 61850 received uinteger 1
26F2
IEC 61850 received uinteger 2
26F4
IEC 61850 received uinteger 3
26F6
IEC 61850 received uinteger 4
26F8
IEC 61850 received uinteger 5
26FA
IEC 61850 received uinteger 6
26FC
IEC 61850 received uinteger 7
26FE
IEC 61850 received uinteger 8
2700
IEC 61850 received uinteger 9
2702
IEC 61850 received uinteger 10
2704
IEC 61850 received uinteger 11
2706
IEC 61850 received uinteger 12
2708
IEC 61850 received uinteger 13
270A
IEC 61850 received uinteger 14
270C
IEC 61850 received uinteger 15
270E
IEC 61850 received uinteger 16
B-14
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
C70 Capacitor Bank Protection and Control System
RANGE
UNITS
STEP
---
1
---
1
0 to 1
---
1
0 to 2
---
1
---
---
---
0 to 1
---
1
0 to 7
---
1
0 to 1
---
1
1 to 32
---
1
0 to 128
---
1
1 to 64
---
1
0 to 1
---
1
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
1
---
1
---
1
---
1
---
1
---
1
---
1
---
1
---
1
---
1
---
1
---
1
---
1
---
1
---
1
---
1
APPENDIX B
FORMAT
DEFAULT
F300
0
F300
0
F102
0 (Disabled)
F109
0 (Self-Reset)
F001
0
F126
0 (No)
F244
6 (H1a)
F102
0 (Disabled)
F001
1
F156
0 (None)
F205
"Rem Ip 1"
F102
0 (Disabled)
F612
0
F612
0
F612
0
F612
0
F612
0
F612
0
F612
0
F612
0
F612
0
F612
0
F612
0
F612
0
F612
0
F612
0
F612
0
F612
0
F003
0
F003
0
F003
0
F003
0
F003
0
F003
0
F003
0
F003
0
F003
0
F003
0
F003
0
F003
0
F003
0
F003
0
F003
0
F003
0
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents