Verifying The Span Configuration - Cisco Nexus 7000 Series Configuration Manual

Hide thumbs Also See for Nexus 7000 Series:
Table of Contents

Advertisement

Verifying the SPAN Configuration

Procedure
Step 1
Step 2
Step 3
Step 4
Step 5
Verifying the SPAN Configuration
To display the SPAN configuration, perform one of the following tasks:
Command
show monitor session {all | session-number | range
session-range} [brief]
show resource monitor-session
show resource monitor-session-extended
show running-config
Cisco Nexus 7000 Series NX-OS System Management Configuration Guide
320
Command or Action
switch# configure terminal
switch(config)# interface type
{module | port}
switch(config)# [no]switchport
monitor exclude header
switch(config)# exit
switch# copy running-config
startup-config
Purpose
Enters global configuration mode.
Enters the interface mode and specifies the port or ports
from which you want to remove the FabricPath and
VNTAG headers.
(Optional)
Removes the FabricPath and VNTAG headers for the
specified SPAN destination ports in the VDC.
Use the no form of the command to preserve the headers
on packets for SPAN destination ports.
(Optional)
Returns to global configuration mode.
(Optional)
Copies the running configuration to the startup
configuration.
Purpose
Displays the SPAN session configuration.
Displays the resources that are available for the
traditional sessions.
Displays the resources that are available for the
extended session.
Displays configuration of the commands for removing
the FabricPath and VNTAG headers for SPAN.
Configuring SPAN

Advertisement

Table of Contents
loading

Table of Contents