Cisco Nexus 7000 Series Configuration Manual page 161

Hide thumbs Also See for Nexus 7000 Series:
Table of Contents

Advertisement

Configuring Smart Call Home
Alert Group
Environmental
and CISCO_TAC
Inventory and
CISCO_TAC
License
Line module
Hardware and
CISCO_TAC
Supervisor
Hardware and
CISCO_TAC
Syslog-group-port
Event Name
FAN_FAILURE
POWER_SUPPLY_ALERT
POWER_SUPPLY_FAILURE
POWER_SUPPLY_SHUTDOWN
TEMPERATURE_ALARM
TEMPERA TURE_MAJOR_ALARM
TEMPERA TURE_MINOR_ALARM
COLD_BOOT
HARDWARE_INSERTION
HARDWARE_REMOVAL
PERIODIC_INVENTORY
LICENSE_VIOLATION
LINEmodule_FAILURE
SUP_FAILURE
PORT_FAILURE
SYSLOG_ALERT
Cisco Nexus 7000 Series NX-OS System Management Configuration Guide
Description
Cooling fan has failed.
Power supply warning has occurred.
Power supply has failed.
Power supply has shut down.
Thermal sensor going bad.
Thermal sensor indicates temperature
has reached operating major
threshold.
Thermal sensor indicates temperature
has reached operating minor
threshold.
Switch is powered up and reset to a
cold boot sequence.
New piece of hardware has been
inserted into the chassis.
Hardware has been removed from the
chassis.
Periodic inventory message has been
generated.
Feature in use is not licensed and is
turned off after grace period
expiration.
Module operation has failed.
Supervisor module operation has
failed.
syslog message that corresponds to
the port facility has been generated.
syslog alert message has been
generated.
Event Triggers
Smart Call
Home Severity
Level
5
6
6
6
6
6
4
2
2
2
2
6
7
7
6
5
133