Chapter 3
Initial Configuration
If the ONS 15454 SONET/SDH node is set up as a proxy server, where one ONS 15454 SONET/SDH
Note
node in the ring acts as a gateway network element (GNE) for the other nodes in the ring, Telnetting over
the GNE firewall to the IP address and slot number of a non-GNE or end network element (ENE) requires
the user's Telnet client to be SOCKS v5 aware (RFC 1928). Configure the Telnet client to recognize the
GNE as the Socks v5 proxy for the Telnet session and to recognize the ENE as the host.
Obtain the node IP address from the LCD on the front of the physical ONS 15454 SONET/SDH or the
Step 1
IP Addr field shown at the CTC shelf view
Identify the slot number containing the targeted ML-Series card from either the physical ONS 15454
Step 2
SONET/SDH or the CTC shelf view
Figure 3-2
Step 3
Use the IP address and the total of the slot number plus 2000 as the Telnet address in your preferred
communication program. For example, for an IP address of 10.92.18.124 and Slot 13, you would enter
or telnet
Cisco ONS 15454 SONET/SDH ML-Series Multilayer Ethernet Card Software Feature and Configuration Guide, R4.0
78-15224-02
CTC Node View Showing IP Address and Slot Number
.
10.92.18.124 2013
(Figure
3-2).
(Figure
3-2). For example, Slot 13.
ML-Series Access
3-3