Common ML-Series POS Configurations
!
router ospf 1
log-adjacency-changes
network 192.168.2.0 0.0.0.255 area 0
network 192.168.3.0 0.0.0.255 area 0
!
The default encapsulation for the ML-Series card is LEX and the corresponding default MTU is 1500
Note
bytes. When connecting to an external POS device, it is important to ensure that both the ML-Series
switch and the external device uses the same configuration for the parameters listed in
Table 4-4
Command
Router(config-if)# encapsulation ppp
or
Router(config-if)# encapsulation hdlc
Router(config-if)#
Router(config-if)# pos flag c2 value

ML-Series Card to G-Series Card

Figure 4-4
Figure 4-4

Router_A Configuration

hostname Router_A
!
interface FastEthernet0
ip address 192.168.1.1 255.255.255.0
!
Cisco ONS 15454 SONET/SDH ML-Series Multilayer Ethernet Card Software Feature and Configuration Guide, R4.0
4-20
ML-Series Parameter Configuration for Connection to a Cisco 12000 GSR-Series Router
show controller pos C2 Byte—Use the show controller pos command to
illustrates a POS configuration between an ML-Series card and a G-Series card.
ML-Series Card to G-Series Card POS Configuration
pos 0
SONET/SDH
192.168.2.1
fast ethernet 0
192.168.1.1
Parameter
Encapsulation—Default encapsulation is HDLC on
GSR. Default encapsulation on ML-Series card is LEX.
verify that the transmit and receive C2 values are the
same.
Sets the C2 byte value. Valid choices are 0 to 255
(decimal). The default value is 0x01 (hex) for LEX.
Ethernet
Chapter 4
Configuring Interfaces
Table
4-4.
78-15224-02