Cisco ONS 15454 DWDM Installation And Operation Manual page 553

Hide thumbs Also See for ONS 15454 DWDM:
Table of Contents

Advertisement

Chapter 11
Maintain the Node
Table 11-4 Incompatibility Alarms for ONS 15454 ETSI (continued)
Shelf Assembly
ETSI
ETSI
ETSI
ETSI
ETSI
ETSI
1. 15454-SA-ETSI (P/N: 800-08708-XX) = ONS 15454 SDH Release 3.3 and later shelf assembly
2. 5A Fan Tray = 15454E-FTA-60V
2A Fan Tray = 15454E-FTA-48V
3. 10G cards = XC-10G, XC-VXL-10G, STM-64, STM-16 AS
4. 2.5G compatible Ethernet cards = E1000-T, E1000-2, E1000T-G, E10002-G, G1000-4, G1K-4
10G compatible Ethernet cards = E1000T-G, E10002-G, G1000-4, G1K-4, ML100T-12, ML1000-2
Open the front door of the shelf assembly. If the shelf assembly does not have a front door, continue with
Step 2
Step
Open the front door lock.
a.
The ONS 15454 comes with a pinned hex key for locking and unlocking the front door. Turn the key
counterclockwise to unlock the door and clockwise to lock it.
Press the door button to release the latch.
b.
Swing the door open.
c.
Remove the front door (optional). If you do not want to remove the door, proceed to
Step 3
Detach the ground strap from either the door or the chassis by removing one of the Kepnuts.
a.
Place the Kepnut back on the stud after the ground strap is removed to avoid misplacement.
b.
Secure the dangling end of the ground strap to the door or chassis with tape.
c.
Push the outer side of the handles on the fan-tray assembly to expose the handles.
Step 4
Step 5
Fold out the retractable handles at the outside edges of the fan tray.
Step 6
Pull the handles and slide the fan-tray assembly one inch (25.4 mm) out of the shelf assembly and wait
until the fans stop.
When the fans have stopped, pull the fan-tray assembly completely out of the shelf assembly.
Step 7
Figure 11-9
September 2004
1
Fan Tray
2A
2A
2A
5A
5A
5A
4.
shows the location of the fan tray on the ONS 15454 ANSI shelf.
2
3
10G Cards
Ethernet Cards
No
Either
Yes
2.5G compatible
Yes
10G compatible
Yes
2.5G compatible
No
Either
Yes
Either
Cisco ONS 15454 DWDM Installation and Operations Guide, R4.7
NTP-G116 Replace the Fan-Tray Assembly
4
Alarms
None
MEA on fan tray, Ethernet
MEA on fan tray
MEA on Ethernet
None
None
Step
4.
11-37