Aic-I Card Specifications - Cisco ONS 15454 DWDM Installation And Operation Manual

Hide thumbs Also See for ONS 15454 DWDM:
Table of Contents

Advertisement

Appendix B
Hardware Specifications
B.3.3 AIC-I Card Specifications
April 2006
Alarm inputs
Number of inputs: 12 without alarm extension panel (AEP), 32 with AEP
Opto-coupler isolated
Label customer provisionable
Severity customer provisionable
Common 32 V output for all alarm inputs
Each input limited to 2 mA
Termination: Wire-wrap on backplane without AEP, on AEP connectors with AEP
Alarm outputs
Number of outputs: 4 (user configurable as inputs) without AEP, 16 with AEP
Switched by opto MOS (metal oxide semiconductor)
Triggered by definable alarm condition
Maximum allowed open circuit voltage: 60 VDC
Maximum allowed closed circuit current: 100 mA
Termination: Wire-wrap on backplane without AEP, on AEP connectors with AEP
Express orderwire/local orderwire (EOW/LOW)
ITU-T G.711, ITU-T G.712, Telcordia GR-253-CORE
A-law, mu-law
Note
Due to the nature of mixed coding, in a mixed-mode A-law/mu-law configuration, the
orderwire is not ITU-T G.712 compliant.
Orderwire party line
Dual tone, multifrequency (DTMF) signaling
User data channel (UDC)
Bit rate: 64 kbps, codirectional
ITU-T G.703
Input/output impedance: 120 ohm
Termination: RJ-11 connectors
Data communications channel (DCC)
Bit rate: 576 kbps
EIA/TIA-485/V11
Input/output impedance: 120 ohm
Termination: RJ-45 connectors
ACC connection for additional alarm interfaces
Connection to AEP
Power monitoring alarming states:
Cisco ONS 15454 DWDM Installation and Operations Guide, R4.7
B.3.3 AIC-I Card Specifications