Chapter 7
Manage Alarms
Check the Suppress Alarms column check box for the port row where you want to suppress alarms
Step 6
(Figure 7-10 on page
Click Apply.
Step 7
Alarms that apply directly to this port will change appearance as described in
raised on the entire card will remain raised.) A raised AS-CMD alarm that shows the port as its object
will appear in either alarm window. For example, if you suppressed alarms for Port 1 on the Slot 16
OC-48 card, the alarm object will show "FAC-16-1."
Return to your originating procedure (NTP).
Step 8

DLP-G130 Discontinue Alarm Suppression

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
If multiple CTC sessions are open, discontinuing suppression in one session will discontinue
Caution
suppression in all other open sessions.
To discontinue alarm suppression for the entire node:
Step 1
a.
b.
Suppressed alarms will reappear in the Alarms window. (They might have previously been cleared from
the window using the Synchronize button.) The AS-CMD alarm with the System object will be cleared
in all views.
Step 2
To discontinue alarm suppression for individual cards:
a.
b.
c.
d.
Suppressed alarms will reappear in the Alarms window. (They might have previously been cleared from
the window using the Synchronize button.) The AS-CMD alarm with the slot object (for example,
SLOT-16) will be cleared in all views.
Step 3
To discontinue alarm suppression for ports, click the following tabs:
November 2004
If the card is an AD-1B or AD-4B card, click the Provisioning > Optical Line > Alarm Profiles >
Alarm Profiles tabs or the Provisioning > Optical Band > Alarm Profiles > Alarm Profiles tabs.
7-25).
This task discontinues alarm suppression and reenables alarm reporting on
a port, card, or node.
None
DLP-G129 Suppress Alarm Reporting, page 7-33
DLP-G46 Log into CTC, page 2-25
As needed
Onsite or remote
Provisioning or higher
In node view, click the Provisioning > Alarm Profiles > Alarm Profiles tab.
Uncheck the Suppress Alarms check box.
In the node view, click the Provisioning > Alarm Profiles > Alarm Profiles tabs.
Locate the card that was suppressed in the slot list.
Uncheck the Suppress Alarms column check box for that slot.
Click Apply.
Cisco ONS 15454 DWDM Installation and Operations Guide, R4.7
DLP-G130 Discontinue Alarm Suppression
Step
2. (However, alarms
7-35