A.6 A.6.19 OC192/STM64 Any Reach Card Specifications
•
•
A.6.19 OC192/STM64 Any Reach Card Specifications
The OC192/STM64 Any Reach card is designated as OC192-XFP in CTC.
Note
The OC192/STM64 Any Reach card has the following specifications:
•
•
•
•
Cisco ONS 15454 Reference Manual, R7.0.1
A-44
Minimum receiver level: –11 dBm
–
Receiver input wavelength range: 1260 to 1565 nm
–
Environmental
Operating temperature: 32 to +131 degrees Fahrenheit (0 to +55 degrees Celsius)
–
Operating humidity: 5 to 95 percent, noncondensing
–
Power consumption: 40.00 W, 0.83 A at –48 V, 136.49 BTU/hr
–
Dimensions
Height: 12.650 in. (321.3 mm)
–
Width: 0.716 in. (18.2 mm)
–
Depth: 9.000 in. (228.6 mm)
–
Depth with backplane connector: 9.250 in. (235 mm)
–
–
Weight not including clam shell: 3.1 lb (1.3 kg)
Line
Bit rate: OC-192 (9.9520 Gbps)
–
Fiber: 1310-nm single-mode for ONS-XC-10G-S1 XFP, 1550-nm single mode for
–
ONS-XC-10G-I2 and ONS-XC-10G-L2 XFPs
Connectors: LC duplex connector for the XFPs
–
Compliance: Telcordia GR-253-CORE
–
Transmitter
Maximum transmitter output power: Depends on SFP (see
–
Specifications, page
A-4)
Minimum transmitter output power: Depends on SFP (see
–
Specifications, page
A-4)
Receiver
Maximum receiver level: Depends on SFP (see
–
page
A-4)
Minimum receiver level: Depends on SFP (see
–
page
A-4)
–
Receiver input wavelength range: 1260 to 1565 nm
Environmental
Operating temperature: 32 to +131 degrees Fahrenheit (0 to +55 degrees Celsius)
–
Operating humidity: 5 to 95 percent, noncondensing
–
Power consumption: 40.00 W, 0.83 A at –48 V, 136.49 BTU/hr
–
Appendix A
Hardware Specifications
A.2 SFP, XFP, and GBIC
A.2 SFP, XFP, and GBIC
A.2 SFP, XFP, and GBIC Specifications,
A.2 SFP, XFP, and GBIC Specifications,
OL-9217-01