Output Program Status

This window can help you determine the status of all mapped programs. The APEX1000
maps input programs to output streams in the same manner, regardless of the Operating
mode. The Output Program Status window shows the programs that are being
remapped to a particular output stream.
The Output Program Status window also shows:
The current encryption mode (if any)
The current encryption status of each program
Each input program is mapped to an output stream, as follows:
1. Input PAT is extracted.
2. Using the input PAT, the corresponding input program number is used to find the
input PMT PID.
3. Using the input PMT PID, the input PMT is extracted.
4. Using the input PMT, the component PIDs and PCR PID are identified and remapped
or remultiplexed to the specified output. The PID values are changed depending on
the PID Remapping configuration parameter.
Status • Reports
APEX1000 All-Purpose Edge QAM Software Version 2.4.x • Installation and Operation Manual
573408-001-a
Figure 12-24 — Output Program Status