Rpc Session Control Pop-Up - Motorola APEX1000 Installation And Operation Manual

All-purpose edge qam
Table of Contents

Advertisement

To configure an RPC Session:
1. Select a Primary and a Secondary GigE interface for each transport stream (must be
either GigE1 and GigE2 or GigE3 and GigE4).
2. Click Apply.
Note: While disabled, the APEX1000 only reports the sessions for the requesting
manager. In addition, you cannot modify Primary and Secondary interfaces if there is an
active session control mapping on the specified output stream.
Item
TS:QAM
Primary GigE IF
Secondary GigE IF
Config All

RPC Session Control Pop-up

Use this window to select a range of QAMs and Primary/Secondary settings:
SDV — Switched Digital Video Controls • RPC Session Control
APEX1000 All-Purpose Edge QAM Software Version 2.4.x • Installation and Operation Manual
573408-001-a
RPC Session Control window field definitions
Definition
Shows the Output Transport Stream number and Output QAM channel.
Specifies a GigE port (1 – 4) as the primary input interface.
Specifies a GigE port (1 – 4) as the secondary input interface.
N/A is also a valid entry.
Opens the RPC Session Control screen (shown below).
B
159

Advertisement

Table of Contents
loading

Table of Contents