System reactions
8.1
System reactions to SINUMERIK alarms
Identifier
COMPBLOCKWITHREORG
Effects
Block preparation has detected an error, which can be rectified by modifying the program.
Reorganization is performed after a program modification.
•
Correction block with reorganization.
Identifier
COMPENSATIONBLOCK
Effects
Block preparation has detected an error, which can be rectified by modifying the program.
•
Correction block.
Identifier
FOLLOWUP
Effects
Follow-up of axes.
•
NC switches to follow-up mode.
Identifier
INTERPRETERSTOP
Effects
Program execution is aborted after all the prepared blocks (IPO buffer) have been processed.
•
Interpreter stop.
Identifier
LOCALREACTION
Effects
•
Local alarm reaction.
Identifier
NOALARMREACTION
Effects
•
No alarm reaction.
Identifier
NOREADY | NCKREACTIONVIEW
Effects
NCK ready off: Active fast braking (i.e. with maximum braking current) of all drives, the controller
enable for all NC axes is deleted, the NC ready relay drops out.
•
NC not ready.
Alarms
Diagnostics Manual 07/2010, 6FC5398-8BP40-0BA0
8
931