61373
[Channel %1: ] Block %2: Mono-directional probe requires SPOS-capable spindle
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Check machine equipment.
61374
[Channel %1: ] Block %2: Probe not calibrated in axis direction %4
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggered by the following cycles: CYCLE982
Remedy:
Calibrate the probe in the specified axis direction.
61375
[Channel %1: ] Block %2: Trigger values of measuring sensor are incompatible
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE971
Remedy:
Trigger values of the tool measuring sensor must be fully described either via the _TP[] / _TPW[] fields or via the setting
data
(SD: 54625-54632 or SD: 54640-54647). A mixture of the two variants is not permitted.
61401
[Channel %1: ] Block %2: Probe does not switch, traversing path limited by software
limit position.
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE961, CYCLE971, CYCLE976, CYCLE977, CYCLE978,
CYCLE998
Remedy:
The position defined by a setpoint value cannot be reached as this would mean overrunning the software limit position.
- Check specified setpoint value.
61402
[Channel %1: ] Block %2: Probe collision, traversing path limited by software limit
position
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm triggered by following cycles: CYCLE977
Remedy:
For the measuring variants Measure web/shaft, the position path in the plane was limited by the software limit position.
The probe switched in the following infeed along the infeed axis.
Check programmed position of software limit position.