NCK alarms
6460
[Channel %1: ] Block %2 Command '%3' can only be programmed for tools. '%4' does
not designate a tool.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Programmed command
%4 = Programmed parameter
Definitions:
The specified command can only be programmed for tools. The command parameter is not a T number or a tool name.
If a multitool has been programmed: The command cannot be programmed for multitools.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct the NC program
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
6462
[Channel %1: ] Block %2 Command '%3' can only be programmed for magazines. '%4'
does not designate a magazine.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Programmed command
%4 = Programmed parameter
Definitions:
The specified command can only be programmed for magazines. The command parameter is not a magazine number
or a magazine name. If a multitool has been programmed: The command cannot be programmed for multitools.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct the NC program
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
6464
[Channel %1: ] Block %2 Command '%3' cannot be programmed for the current
multitool distance coding '%4'
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Programmed command
%4 = Type of distance coding
Definitions:
$TC_MTPPL can only be programmed if $TC_MTP_KD has a value of 2.
$TC_MTPPA can only be programmed if $TC_MTP_KD has a value of 3.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct the NC program
Program
Clear alarm with NC START or RESET key and continue the program.