Reaction:
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Check and correct the axis assignment in the compensa-
tion table. If the error cannot be found, the alarm can be suppressed by switching off the table
($SN_CEC_TABLE_ENABLE) or switching off compensation in the axis ($MA_CEC_ENABLE).
Program
Clear alarm with the RESET key. Restart part program
Continuation:
20123
Axis %1: different output assignment of multiplied tables
Parameters:
%1 = Axis name, spindle number
Definitions:
Interpolatory compensation with tables. The two tables whose outputs are to be multiplied together have different out-
put axes assigned to them. The compensation in this axis is automatically switched off.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Check and correct the characteristic data in the compen-
sation table ($AN_CEC_OUTPUT_AXIS and $AN_CEC_MULT_BY_TABLE).
If the error cannot be found, the alarm can be suppressed by switching off the compensation in the axis
($MA_CEC_ENABLE) or the tables, ($SN_CEC_TABLE_ENABLE).
Program
Clear alarm with the RESET key. Restart part program
Continuation:
20124
Axis %1: sum of compensation values too large
Parameters:
%1 = Axis name, spindle number
Definitions:
The sum of the compensation values from all tables assigned to the axis had exceeded the limit value MD32720
$MA_CEC_MAX_SUM and had to be limited. Contour errors could have occurred as a result.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Check characteristic data of the compensation tables assigned to the axis.
Check characteristic curves in the tables ($AN_CEC).
Program
Clear alarm with the RESET key. Restart part program
Continuation:
20125
Axis %1: change of compensation value is too rapid
Parameters:
%1 = Axis name, spindle number
Definitions:
The compensation value has changed more rapidly than has been allowed for in MD32730 $MA_CEC_MAX_VELO.
It had to be limited temporarily. The missing section is repeated later but contour errors might have occurred.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Check characteristic data of the compensation tables assigned to the axis.
Check characteristic curves in the tables ($AN_CEC). Possibly one of the input axes has moved more rapidly than
provided for.
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
311