10634
[Channel %1: ] Axis %2, tool radius compensation is inactive for type %3 working area
limitation, reason: The tool is not oriented parallel to the axis.
Parameters:
%1 = Channel number
%2 = Axis, spindle
%3 = 0: BCS, 1: WCS / SZS
Definitions:
The tool radius compensation of the working area limitation of the stated axis is not taken into account.
Reason: The tool is not oriented parallel to the axis (e.g. because toolcarrier or transformation is active).
The alarm is reported in JOG mode.
Reaction:
Alarm display.
Remedy:
The tool radius compensation for working area limitations in JOG mode can only be taken into account if the tool is
parallel to the axis.
Active transformation and toolcarrier must be switched off for this function.
Program
Clear alarm with the Delete key or NC START.
Continuation:
10635
[Channel %1: ] Axis %2, tool radius compensation is inactive for type %3 working area
limitation, reason: no milling or drilling tool.
Parameters:
%1 = Channel number
%2 = Axis, spindle
%3 = 0: BCS, 1: WCS / SZS
Definitions:
The tool radius compensation of the working area limitation of the stated axis is not taken into account.
Reason: The tool must be of type milling cutter or drill.
The alarm is reported in JOG mode.
Reaction:
Alarm display.
Remedy:
The tool radius compensation for working area limitations in JOG mode can only be taken into account for milling or
drilling tools.
Program
Clear alarm with the Delete key or NC START.
Continuation:
10636
[Channel %1: ] Axis %2, tool radius compensation is inactive for type %3 working area
limitation, reason: Transformation is active.
Parameters:
%1 = Channel number
%2 = Axis, spindle
%3 = 0: BCS, 1: WCS / SZS
Definitions:
The tool radius compensation of the working area limitation of the stated axis is not taken into account.
Reason: A transformation is active.
The alarm is reported in JOG mode.
Reaction:
Alarm display.
Remedy:
The tool radius compensation for working area limitations in JOG mode cannot be taken into account if transfomation
is active.
Program
Clear alarm with the Delete key or NC START.
Continuation:
10637
[Channel %1: ] Axis %2, tool radius compensation is inactive for type %3 working area
limitation, reason: Tool not active.
Parameters:
%1 = Channel number
%2 = Axis, spindle
%3 = 0: BCS, 1: WCS / SZS