Configuring Port Rate Limiting; Section 3.6.7, "Configuring Port Rate Limiting - Siemens RUGGEDCOM ROS v4.3 User Manual

Table of Contents

Advertisement

Chapter 3
Device Management
Parameter
LFI
Alarm
NOTE
If one end of the link is fixed to a specific speed and duplex type and the peer auto-negotiates,
there is a strong possibility that the link will either fail to raise, or raise with the wrong settings on
the auto-negotiating side. The auto-negotiating peer will fall back to half-duplex operation, even
when the fixed side is full duplex. Full-duplex operation requires that both ends are configured
as such or else severe frame loss will occur during heavy network traffic. At lower traffic volumes
the link may display few, if any, errors. As the traffic volume rises, the fixed negotiation side will
begin to experience dropped packets, while the auto-negotiating side will experience excessive
collisions. Ultimately, as traffic load approaches 100%, the link will become entirely unusable.
These problems can be avoided by always configuring ports to the appropriate fixed values.
4.
Click Apply.
Section 3.6.7

Configuring Port Rate Limiting

To configure port rate limiting, do the following:
Navigate to Ethernet Ports » Configure Port Rate Limiting . The Port Rate Limiting table appears.
1.
74
Description
When the port is half-duplex it is accomplished using
'backpressure' where the switch simulates collisions causing the
sending device to retry transmissions according to the Ethernet
backoff algorithm.
When the port is full-duplex it is accomplished using PAUSE
frames which causes the sending device to stop transmitting for a
certain period of time.
Synopsis:   { Off, On }
Default:   Off
Enabling Link-Fault-Indication (LFI) inhibits transmitting link
integrity signal when the receive link has failed. This allows the
device at far end to detect link failure under all circumstances.
NOTE
This feature must not be enabled at both ends of a
fiber link.
Synopsis:   { On, Off }
Default:   On
Disabling link state alarms will prevent alarms and LinkUp and
LinkDown SNMP traps from being sent for that port.
RUGGEDCOM ROS
User Guide
Configuring Port Rate Limiting