Chapter 4
System Administration
8
Figure 70: Alarms Form
1. Name Box 2. Level Box 3. Latch Box 4. Trap Box 5. Log Box 6. LED & Relay Box 7. Refresh Time Box 8. Apply Button
9. Reload Button
3.
Configure the following parameter(s) as required:
Parameter
Name
Level
Latch
Trap
Log
120
Description
Synopsis: Any 34 characters
Default: sys_alarm
The alarm name, as obtained through the alarms CLI command.
Synopsis: { EMRG, ALRT, CRIT, ERRO, WARN, NOTE, INFO, DEBG }
Severity level of the alarm:
• EMERG - The device has had a serious failure that caused a
system reboot.
• ALERT - The device has had a serious failure that did not cause a
system reboot.
• CRITICAL - The device has a serious unrecoverable problem.
• ERROR - The device has a recoverable problem that does not
seriously affect operation.
• WARNING - Possibly serious problem affecting overall system
operation.
• NOTIFY - Condition detected that is not expected or not
allowed.
• INFO - Event which is a part of normal operation, e.g. cold start,
user login etc.
• DEBUG - Intended for factory troubleshooting only.
This parameter is not configurable.
Synopsis: { On, Off }
Default: Off
Enables latching occurrence of this alarm in the Alarms Table.
Synopsis: { On, Off }
Default: Off
Enables sending an SNMP trap for this alarm.
Synopsis: { On, Off }
Default: Off
RUGGEDCOM ROS
User Guide
1
2
3
4
5
6
7
9
Configuring an Alarm