FF8 0 07: Bus Monitor (for factory use)

0
System
Configuration
Bus Monitor Save Control
(
(all CPCs) - Version 1.0 or higher
Save internal bus communication, which can then be used to investigate a
FF1
problem that occurs.
System
FF2
Trunks
FF3
Notes:
Extensions
Related Programming:
FF4
FF-/Soft Keys
FF5
Groups
Trigger Codes
(all CPCs) - Version 1.0 or higher
Specify up to 5 Trigger Codes, which are used for saving Bus Monitor information.
FF6
TRS/ARS
FF7
Applications
FF8
Maintenance
Notes:
This address should be used only under the supervision of Panasonic Technical Support.
Related Programming:
Appendix A
Appendix B
576-13-400
FF8
0
07
0
FF8
0 07
0
01-03=for Code 1
04-06=for Code 2
07-09=for Code 3
10-12=for Code 4
13-15=for Code 5
DBS 576 (USA) issued 05/20/98
00
Hold
(0 or 1)
0=Stop/Do not save. (default)
1=Start.
(01-15)
Hold
(code)
(see table below)