Auto-Configuration (For Single-Cabinet Systems Only) - Panasonic DBS-576 Technical Manual

Section 400 programming
Hide thumbs Also See for DBS-576:
Table of Contents

Advertisement

Introduction to DBS 576 Programming

Auto-Configuration (for single-cabinet systems only)

Introduction
This procedure will automatically configure a single-cabinet system for a selectable
set of pre-defined settings (see table, next page).
1. Set the CODE rotary switch to 1.
0
System
Configuration
2. Set the RAM HOLD switch to OFF.
3. Hold in the MODE button on the CPC card,
FF1
System
FF2
4. Move the RAM HOLD switch to ON.
Trunks
5. At an installed extension display phone, press
FF3
Extensions
6. Dial the desired System Configuration
FF4
FF-/Soft Keys
7. Press HOLD.
8. Press ON/OFF.
FF5
9. Wait for the initialize auto-configuration
Groups
FF6
TRS/ARS
FF7
Applications
FF8
Maintenance
Appendix A
Appendix B
Intro-6
and either press the RESET button or power-
on the system.
Wait for the MN LED to come on before
releasing the MODE button.
ON/OFF. The phone should display:
 
  
Pattern No. 1-6 (see table, next page).
process to complete.
Successful completion will be indicated by
the system returning to normal operating
mode (the main screen will appear on the
phone):

DBS 576 (USA) issued 05/20/98
00:07 Wed JAN 01
100
EXT100
  
 
  
 
  



 

Section 400-Programming
The CPC-96 Card
(front edge, facing out from cabinet)
CN3
(for PC Upgrade Kit)
RUN LED (MPU)
MJ LED
MN LED
RAM HOLD switch
RESET button
CODE rotary switch
MODE button
MOH plug-in
576-13-400
Introduction
0
System
Configuration
FF1
System
FF2
Trunks
FF3
Extensions
FF4
FF-/Soft Keys
FF5
Groups
FF6
TRS/ARS
FF7
Applications
FF8
Maintenance
Appendix A
Appendix B

Advertisement

Table of Contents
loading

Table of Contents