HP StorageWorks 2/16 - SAN Switch Manual page 221

Hp storageworks fabric os 3.x document addendum (aa-rw24a-te, january 2005)
Hide thumbs Also See for StorageWorks 2/16 - SAN Switch:
Table of Contents

Advertisement

switchState
switchMode
switchRole
switchDomain
switchId
switchWwn
switchBeacon
Zoning
The switch summary is followed by one line per port:
port number
module type
port speed
Fabric OS 3.x Document Addendum
The switch's state: Online, Offline, Testing, or Faulty.
The switch's mode: Interop or Native.
The switch's role: Principal, Subordinate, or Disabled.
The switch's Domain ID: 0 through 31 or 1 through 239.
The switch's embedded port D_ID.
The switch's World Wide Name.
The switch's beaconing state: either ON or OFF.
The switch's zoning state (either ON or OFF) and effective
zone configuration, within parenthesis.
The port number: 0 through 7 or 0 through 15.
The port module type (GBIC or other):
— No: module present
— sw: Shortwave laser
— lw: Longwave laser
— cu: Copper
— id: Serial ID
Use the gbicshow command to display whether a serial ID
GBIC is sw, lw, or cu.
The port's link speed:
— 1G: Full speed, 1 Gbit/sec.
— 2G: Double speed, 2 Gbit/sec.
— AN: Speed autonegotiation enabled.
— N1: Speed negotiated to full speed.
— N2: Speed negotiated to double speed.
Fabric OS reference guide