SEC-PIDCHGERR, PID Change failed: Size check failed
Message
<timestamp>
ERROR SEC-PIDCHGERR, 2, PID Change failed: Size check failed. <defined
status> <active status>
Probable Cause
Either the new defined or new active policy was too large after modifying the area ID. The
status values can be defined, active, or both. A negative value means that a policy set
was failed by the daemon.
Recommended Action
Reduce the size of the specified policy database.
Severity
ERROR
SEC-PIDCHGERR, Change failed: Can't get sec_db
Message
<timestamp>
ERROR SEC-PIDCHGERR, 2, Change failed: Switch is busy. Operation failed.
Probable Cause
The switch security daemon is busy. The status values can be defined, active, or both. A
negative value means that a policy set was failed by the daemon.
Recommended Action
For the first reject, wait a few minutes and then resubmit the transaction. Fabric-wide
commands might take a few minutes to propagate throughout the fabric. Make sure to leave
enough time so your commands do not overlap in the fabric.
Severity
ERROR