HP StorageWorks 2/16 - SAN Switch Manual page 102

Hp storageworks fabric os 3.x document addendum (aa-rw24a-te, january 2005)
Hide thumbs Also See for StorageWorks 2/16 - SAN Switch:
Table of Contents

Advertisement

Diagnostic and system error messages reference guide
Severity
CRITICAL
DIAG-PORTABSENT
Message
<timestamp>
CRITICAL DIAG-PORTABSENT, 1, <test name>, pass <number>,
Pt<port info> is not present, cannot run test,
Err# <error code>
Probable Cause
The port is not present. This can be caused by a faulty cable or deteriorated SFP. It can also
indicate more serious problems in the motherboard or ASIC. This message is generated by the
portloopbacktest or spinsilk command. The error code value is for internal use
only.
Recommended Action
Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the
problem persists:
Severity
CRITICAL
DIAG-PORTDIED
Message
<timestamp>
CRITICAL DIAG-PORTDIED, 1, DIAG-PORTDIED
<test name>, pass <number>,
Pt<port info><speed> Was Active but Went Inactive (Offline),
Err# <error code>
Probable Cause
The port was in loopback mode and then went inactive. This can be caused by a faulty cable or
deteriorated SFP. It can also indicate more serious problems in the motherboard or ASIC. This
message is generated by the crossporttest, portloopbacktest, or spinsilk
command. The error code value is for internal use only.
102
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Fabric OS 3.x Document Addendum