Diagnostic and system error messages reference guide
DIAG-STATS (FTX)
Message
<timestamp>
CRITICAL DIAG-STATS (FTX), 1, <test name>, pass <number>,
Pt<port info> FramesTx Counter Wrong, is <actual value> sb <expected
value>,
Err# <error code>
Probable Cause
The port counter value did not match the number of frames actually transmitted. In this case,
FramesTx equals the number of frames transmitted. This can be caused by a faulty cable or
deteriorated SFP. It can also indicate more serious problems in the motherboard or ASIC. This
message is generated by the portloopbacktest command. The error code value is
for internal use only.
Recommended Action
Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the
problem persists:
Severity
CRITICAL
DIAG-TBRAM_DEC_RWTEST
Message
<timestamp>
CRITICAL DIAG-TBRAM_DEC_RWTEST, 1, <test name>, pass <number>,
Pt<port info> Failed Turbo RAM dec r/w test:
phy=0x<address> wrd cnt=<cnt> inc size=<size> bytes
rpt=0x<actual pattern> wpt=0x<expected pattern> msk=0x<mask value>
Err# <error code>
Probable Cause
The ASIC internal registers failed the read-modify-write operation. This usually indicates an
ASIC failure. This message is generated by the turboramtest command. The error
code value is for internal use only.
108
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.