Toshiba GR200 Series Instruction Manual page 1257

Line differential protection ied
Hide thumbs Also See for GR200 Series:
Table of Contents

Advertisement

Generic supervision tasks
Displaying errors regarding the common problems are summarized in Table 10.2-1; the error
will be cleared when recovered
Table 10.2-1 Supervision items and error levels for generic
Sec.No.
Supervision items(Screen message)
10.2.1
Mismatch between ROM and RAM data (ROM/RAM error)
10.2.2
Supervision of check-sum error (SUM error)
10.2.3
Supervision of RAM (RAM error)
10.2.4
Supervision of ECC on memory (ECC error)
10.2.5
Supervision of MRAM (MRAM)
10.2.6
Supervision of FPGA (FPGA error)
10.2.7
Supervision of program codes (CPU error)
10.2.8
Supervision of task operation (RUN error)
10.2.9
Detecting non-maskable interrupt (NMI error)
10.2.10
Supervision of sampling period (SMP error)
10.2.11
Supervision of setting data (Setting error)
10.2.12
Supervision of real-time clock (RTC error)
10.2.13
Supervision of analog input data on VCTs (AI ACC error)
10.2.14
Abnormal currents flowing in CTs (CT error)
10.2.15
Current transformer failure (CT fail)
10.2.16
Supervision of the current in zero-sequence (I0 error)
10.2.17
Supervision of voltage in negative-sequence (V2 error)
10.2.18
Supervision of voltage in zero-sequence (VZ error)
10.2.19
Supervision of binary IO module#1 (BIO#1 error)
10.2.20
Supervision of binary IO module#2 (BIO#2 error)
10.2.21
Supervision of binary IO module#3 (BIO#3 error)
10.2.22
Supervision of binary IO module#4 (BIO#4 error)
10.2.23
Supervision of binary IO module#5 (BIO#5 error)
10.2.24
Supervision of binary IO module#6 (BIO#6 error)
10.2.25
Supervision of binary IO module#7 (BIO#7 error)
10.2.26
Supervision of binary IO module#8 (BIO#8 error)
10.2.27
Supervision of human machine interface (HMI error)
10.2.28
Supervision of power supply module (Power error)
10.2.29
Supervision of data in PLC function (PLC data error)
10.2.30
Voltage transformer failure (VT fail)
10.2.31
Supervision of circuit breaker contacts (CB1/CB2 fail)
10.2.32
Supervision of disconnector contacts (DS fail)
- 1234 -
6F2S1914 (0.49)
Detailed
Error
Info.
Lvl
LED
Displayed
1
ON
Displayed
1
ON
Displayed
1
ON
Displayed
1
ON
Displayed
1
ON
Displayed
1
ON
Displayed
1
ON
Displayed
1
ON
Displayed
1
ON
Displayed
1
ON
Displayed
1
ON
Displayed
3
ON
Displayed
1
ON
3
ON
N/A
3
ON
N/A
3
ON
N/A
3
ON
N/A
3
ON
N/A
Displayed
1
ON
Displayed
1
ON
Displayed
1
ON
Displayed
1
ON
Displayed
1
ON
Displayed
1
ON
Displayed
1
ON
Displayed
1
ON
Displayed
3
ON
3
ON
N/A
Displayed
3
ON
3
ON
N/A
3
ON
N/A
3
ON
N/A
GRL200 (Soft 033 & 037)

Advertisement

Table of Contents
loading

Table of Contents