2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in
place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. Make sure that the DIMM baffles are in place if applicable
5. If the problem persists and there are no other DIMMs with the same indication, replace the DIMM.
• FQXSPMA0012M: An Over-Temperature Condition has been detected on the
[PhysicalMemoryElementName] on Subsystem [MemoryElementName].
This message is for the use case when an implementation has detected an Over Temperature Condition
for Memory that has been Detected.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Temperature
SNMP Trap ID: 0
CIM Prefix: PLAT CIM ID: 0146
User Action:
Need thermal team input
• FQXSPMA2003I: [PhysicalMemoryElementName] Removed on Subsystem [MemoryElementName].
This message is for the use case when an implementation has detected Memory has been Removed.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0129
User Action:
Need XCC team to identify sensor name or trigger situation.
• FQXSPMA2005I: The System [ComputerSystemElementName] has detected a POST Error
deassertion.
This message is for the use case when an implementation has detected that Post Error has deasserted.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Memory
SNMP Trap ID: 41
CIM Prefix: PLAT CIM ID: 0185
User Action:
Information only; no action is required
• FQXSPMA2007I: Scrub Failure for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName] has recovered.
This message is for the use case when an implementation has detected a Memory Scrub failure recovery.
Severity: Info
Serviceable: No
56