Lenovo ThinkSystem SD650 Manual page 183

Hide thumbs Also See for ThinkSystem SD650:
Table of Contents

Advertisement

User Action:
Information only; no action is required.
• FQXSFPU4048I: A request was made to update the TPM 2.0 firmware to version 1.3.2.20.
Severity: Info
User Action:
Information only; no action is required.
• FQXSFPU4049I: TPM Firmware update successful.
Severity: Info
User Action:
Information only; no action is required.
• FQXSFPU4050G: Failed to update TPM Firmware.
Severity: Warning
User Action:
Complete the following steps:
1. Clear TPM via TPM operation and retry TPM firmware update by following the instructions in your
product user guides. Go to https://thinksystem.lenovofiles.com/help/topic/com.lenovo.thinksystem.
common.nav.doc/portfolio.html and click your product link. Usually, the TPM update information is
located in "System board replacement" section in "Hardware replacement procedures".
2. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFPU4051G: Undefined TPM_TCM_POLICY found
Severity: Warning
User Action:
Complete the following steps:
1. Reboot the system.
2. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFPU4052G: TPM_TCM_POLICY is not locked
Severity: Warning
User Action:
Complete the following steps:
1. Reboot the system.
2. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFPU4053G: System TPM_TCM_POLICY does not match the planar.
Severity: Warning
User Action:
Complete the following steps:
1. Remove any newly added TPM/TCM card from the planar or re-install the original TPM/TCM card
that shipped with the system.
2. Reboot the system.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
.