Node is turned off(DC-Off)
Severity
Info
Serviceable
Automatically notify support
User Action
1. No user action needed.
• C6 : Second_Perm_Fail
Node post boot continue permission is denied. Node power on process stops at POST and node is
automatically turned off(DC-OFF) after a few minutes.
Severity
Warning
Serviceable
Automatically notify support
User Action
Complete the following steps:
1. Make sure that the node configuration meet the power limitation of current power supply
configuration.
2. Make sure that there is no mismatch of PSU nor non-supported PSU installed.
• C7 : Restore_Cap_Fail
Previously set power capping values cannot be restored
Severity
Warning
Serviceable
Automatically notify support
User Action
Complete the following steps:
1. Make sure that FPC USB key is installed. Check if all power supplies are properly installed and in
healthy condition.
2. If all good, reconfigure power capping values when needed.
• C8 : EPOW_OUT
Node is notified of PSU AC lost condition. Node could enter power throttling state and perfomrance could
be affected.
Severity
Non-Recoverable
Serviceable
Automatically notify support
User Action
Complete the following steps:
.
243