Lenovo ThinkSystem SD650 Manual page 160

Hide thumbs Also See for ThinkSystem SD650:
Table of Contents

Advertisement

Complete the following steps:
1. Ensure one or more DIMMs are installed in the server.
2. Resolve existing memory errors if they are present.
3. If no memory fault is recorded in the logs and no DIMM connector error LEDs are lit, verify that all
DIMM connectors are enabled using the Setup utility or the OneCLI utility.
4. Reseat all DIMMs ensuring that DIMMs are installed in the correct population sequence, according to
the service information for this product.
5. Clear CMOS memory. Note that all firmware settings will revert to the defaults.
6. Reflash UEFI firmware.
7. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0006I: [arg1] DIMM [arg2] has been detected, the DIMM serial number is [arg3].
Severity: Info
Parameters:
[arg1] :Unqualified/Non Lenovo [arg2]: Dimm Silk Label, 1-based [arg3]: Dimm serial number.
User Action:
Complete the following steps:
1. If this information event is logged in the XCC event log, the server does have unqualified memory
installed.
2. The memory installed may not be covered under warranty.
3. Without qualified memory, speeds supported above industry standards will not be enabled.
4. Contact your Local Sales Representative or Authorized Business Partner to order qualified memory
to replace the unqualified DIMM(s).
5. After you install qualified memory and power up the server, check to ensure this informational event
is not logged again.
6. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0007I: [arg1] DIMM number [arg2] has been replaced. [arg3]
Severity: Info
Parameters:
[arg1] :Unqualified/Non Lenovo [arg2]: Dimm Silk Label, 1-based [arg3]: DIMM info (S/N, FRU and UDI.), e.
g. "739E68ED-VC10 FRU 0123456"
User Action:
Complete the following steps:
1. This event should be followed by a recent FQXSFMA0006I event denoting the server does have
unqualified memory installed.
2. Information only; no action is required.
• FQXSFMA0008I: DIMM [arg1] POST memory test failure has been recovered. [arg2]
Severity: Info
Parameters:
[arg1]: DIMM slot silklabel [arg2]: DIMM identifier consists of S/N, FRU and UDI, e.g. "739E68ED-VC10
FRU 0123456"
User Action:
156
ThinkSystem SD650 Dual Node DWC Tray and NeXtScale n1200 DWC Enclosure Messages and Codes Reference

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nextscale n12007x585468

Table of Contents