Lenovo ThinkSystem SD650 Manual page 158

Hide thumbs Also See for ThinkSystem SD650:
Table of Contents

Advertisement

Note: The solution for this error may involve a system board replacement. If TPM encryption has
been enabled, back up TPM Encryption Recovery Key.
• FQXSFMA0001I: DIMM [arg1] Disable has been recovered. [arg2]
Severity: Info
Parameters:
[arg1]: DIMM slot silklabel [arg2]: DIMM identifier consists of S/N, FRU and UDI, e.g. "739E68ED-VC10
FRU 0123456"
User Action:
Information only; no action is required.
• FQXSFMA0001M: DIMM [arg1] has been disabled due to an error detected during POST. [arg2]
Severity: Error
Parameters:
[arg1]: DIMM slot silklabel [arg2]: DIMM identifier consists of S/N, FRU and UDI, e.g. "739E68ED-VC10
FRU 0123456"
User Action:
Complete the following steps:
1. Reseat the affected DIMM (Note: The event Log might contain a recent FQXSFMA0011I event
denoting detected change in DIMM population that could be related to this problem.)
2. Boot to F1 setup and enable the DIMM (For AMD, do not need to enable DIMM in Setup). Reboot the
system.
3. Update UEFI firmware to the latest version.
4. If the problem persists, collect Service Data logs and contact Lenovo Support.
Note: The solution for this error may involve a system board replacement. If TPM encryption has
been enabled, back up TPM Encryption Recovery Key.
• FQXSFMA0002I: The uncorrectable memory error state has been cleared.
Severity: Info
User Action:
Information only; no action is required.
• FQXSFMA0002M: An uncorrectable memory error has been detected on DIMM [arg1] at address
[arg2]. [arg3]
Severity: Error
Parameters:
[arg1]: Dimm Silk Label, 1-based [arg2]: Address of the system where error ocurred [arg3]: DIMM identifier
consists of S/N, FRU and UDI, e.g. "739E68ED-VC10 FRU 0123456"
User Action:
Complete the following steps:
1. Check Lenovo Support site for an applicable service bulletin or firmware update that applies to this
memory error.
2. Reseat the affected DIMM (Note: The event Log might contain a recent FQXSFMA0011I event
denoting detected change in DIMM population that could be related to this problem.)
154
ThinkSystem SD650 Dual Node DWC Tray and NeXtScale n1200 DWC Enclosure Messages and Codes Reference

Advertisement