Note: The solution for this error may involve a system board replacement. If TPM encryption has
been enabled, back up TPM Encryption Recovery Key.
• FQXSFPU4041I: TPM Firmware update is in progress. Please DO NOT power off or reset system.
Severity: Info
User Action:
Information only; no action is required.
• FQXSFPU4042I: TPM Firmware update is finished, rebooting system to take effect.
Severity: Info
User Action:
Information only; no action is required.
• FQXSFPU4043G: TPM Firmware update aborted. System is rebooting...
Severity: Warning
User Action:
Information only; no action is required.
• FQXSFPU4044I: The current TPM firmware version could not support TPM version toggling.
Severity: Info
User Action:
Information only; no action is required.
• FQXSFPU4045G: Physical Presence is not asserted, abort TPM Firmware upgrade.
Severity: Warning
User Action:
Complete the following steps:
1. ASSERT TPM Physical presence jumper by following System Service Manual, ref. https://
thinksystem.lenovofiles.com/help/index.jsp navigate to ThinkSystem SR850P Types 7D2F, 7D2G,
7D2H > Hardware replacement procedures > motherboard replacement > Enable TPM/TCM > Assert
Physical Presence.
2. Boot system into F1 setup, check TPM status make sure TPM is available, and the TPM firmware
version support TPM Toggling, ref. https://thinksystem.lenovofiles.com/help/index.jsp navigate to
UEFI manual for ThinkSystem server > ThinkSystem server with AMD EPYC (1-socket, 1st, 2nd, 3rd
Gen) > System Setup Utility interface > Security menu > TPM Toggling.
3. Reboot system and retry the TPM FW toggle, ref. https://thinksystem.lenovofiles.com/help/index.jsp
navigate to ThinkSystem SR850P Types 7D2F, 7D2G, 7D2H > Hardware replacement procedures >
motherboard replacement>Enable TPM/TCM>Set the TPM version.
4. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFPU4046I: TPM Firmware will be updated from TPM1.2 to TPM2.0.
Severity: Info
User Action:
Information only; no action is required.
• FQXSFPU4047I: TPM Firmware will be updated from TPM2.0 to TPM1.2.
Severity: Info
178
ThinkSystem SD650 Dual Node DWC Tray and NeXtScale n1200 DWC Enclosure Messages and Codes Reference