(4) Remove the polygon assembly together with the polygon spacer.
(4) #1
[Remove] B3x6 (x2)
[Remove] B3x12 (x4)
Polygon cover
Polygonal mirror assembly
(attention to its orientation)
[Remove] Screw (x4)
Polygonal mirror face
DETAIL A
009-058-02
009-058-00
08.30.2001 FM3142 (1)
10.20.2000 FM2732 (2)
Ground cable
Top cover
(4) #3
(4) #4
Polygon spacer
Thick
Filter
CR-IR347 Service Manual
(4)
#2 [Remove] B3x8 (x5)
Ground cable
Filter
Thin
Clamp
(3) #1
[Remove] B3x8
(4) #5
[Cut] Tie
MC - 271
Ground cable
A
(3) #2
[Remove] Screw (x2)
Polygon driver
FR7H3710.EPS
MC - 271