Canon iPF9000S Troubleshooting Manual page 67

Ipf8000 series; ipf9000 series; ipf800 series; ipf700 series; ipf650 series; ipf750 series; ipf5000 series; ipf6000 series; ipf500 series; ipf600 series
Hide thumbs Also See for iPF9000S:
Table of Contents

Advertisement

Code
Panel display
(last 4
Large LCD
digits)
!Spectrophotometer
2F60
(SP) Unit not
connected.
Turn off power and
attach
Spectrophotometer
Unit.
Hardware error
2F61
038A0002-2F61
Turn off printer, wait a
while, then turn it on
again.
Hardware error
2F62
038A0002-2F62
Turn off printer, wait a
while, then turn it on
again.
Hardware error
2F63
038A0002-2F63
Turn off printer, wait a
while, then turn it on
again.
Hardware error
2F65
038A0002-2F65
Turn off printer, wait a
while, then turn it on
again.
Hardware error
2F66
038A0002-2F66
Turn off printer, wait a
while, then turn it on
again.
Hardware error
2F67
038A0002-2F67
Turn off printer, wait a
while, then turn it on
again.
Hardware error
2F68
038A0002-2F68
Turn off printer, wait a
while, then turn it on
again.
Explanation/Detection sequence
Small LCD
SP unit won't return signals.
UART communication error.
(Data transfer volume in
consistency, checksum error etc.)
When transmitting specified pulses
to
respond to SP CP-HR sensor.
SP unit landing sensor won't
respond when a predefined pulse is
sent to the up and down motor.
When a predefined pulse is sent to
the lifting motor, the HP sensor in
SP unit won't respond.
Blast fan won't return signals.
Embedded FlashROM read/ write
error
Spectrophotometer EEPROM
read/write error
2-55
SP CR, the SP CR won't
Chapter 2 Indexes by Case
Remedial Action
(★: Reference fault
isolation procedure or tool)
①Install SP unit.
②Replace signal line.
③ Replace
connection.
③Replace SP unit PCB.
①Replace signal line.
② Replace
connection.
③Replace SP unit PCB
① Replace SP unit
PCB.
②Replace lines
around SP CR.
③Replace CR motor.
①Replace up and
down drive U.
②Replace landing
sensor.
③Re-install delivery
guide.
④Replace SP unit
PCB
①Replace up and
down drive U.
②Replace landing
sensor.
③Re-install delivery
guide.
④Replace SP unit
PCB
①Replace fan
②Replace signal
lines
③Replace SP unit
PCB
①Replace SP unit
PCB
①Replace SP unit
PCB