Canon iPF9000S Troubleshooting Manual page 62

Ipf8000 series; ipf9000 series; ipf800 series; ipf700 series; ipf650 series; ipf750 series; ipf5000 series; ipf6000 series; ipf500 series; ipf600 series
Hide thumbs Also See for iPF9000S:
Table of Contents

Advertisement

Panel display
Code
(last 4
Large LCD
digits)
2F2D
Cassette not
working.
Turn off printer,
wait, then
turn on again.
2F2E
Hardware error.
03130031-2F2E
Turn off printer,
wait, then
turn on again.
2F2F
Hardware error.
03800500-2F2F
Turn off printer,
wait, then
turn on again.
2F30
Hardware error.
03800500-2F30
Turn off printer,
wait, then
turn on again.
Small LCD 1
Power On
Cassette operation disabled
Again
A PWM duty of 100% has lasted for 200
Cassette Motion
msec in a cassette operation.
Error
Power On
Roll shift timeout
Again
No sensor has been detected during a roll
Roll Motion
operation involving sensor detection.
Timeout
Power On
Non-ejection detection error
Again
As a result of nozzle checking made by the
Eject. Detect
head management sensor unit:
①All 640 nozzles in a nozzle line are
Err
② At least 50 nozzles have been found
Reference 1) As for the detection condition ① above, in the
iPF650/750, iPF6300/6350, and iPF8300 series or later, the error
codes are broken up into 2F40,2F41,2F42,2F43,2F44, and 2F47
depending on the non-ejection conditions.
Reference 2) Error 2F2F,2F40,2F41,2F42,2F43,2F44, and 2F47
are detected in the following order.
①Determines signal level (2F47) of head management sensor
②Determines complete non-ejection of all colors (2F40)
③Determines multiple mismatches (2F2F)
④Determines complete non-ejection of a single color (2F41)
⑤Determines complete non-ejection of one line (2F42)
⑥Determines complete non-ejection of 640 nozzles (2F43)
⑦Determines non-ejection of more than 320 nozzles (2F44)
Reference 3) The amount of change (between non-ejecting and
ejecting nozzle counts) from the last session of nozzle checking is
defined as the amount of mismatch.
Power On
Non-ejection detecting position error
Again
No detectable region has been found during
Eject. Detect
non-ejection position adjustment.
Err
2-50
Explanation/Detection sequence
non-discharging.
mismatched in a nozzle line of 640 nozzles
since the last session of detection.
Chapter 2 Indexes by Case
Remedial Action
(★: Reference fault
isolation procedure
or tool)
①Check the
cassette motor
and the drive
circuit.
②Check the
cassette
encoder
sensor.
Go to ★200C
(P3-8).
①Check whether
any foreign
matter such as
paper slip
exists on the
head
management
sensor optical
axis.
②Light
interception
due to ink
accumulation.
⇒Remove the
ink/ Replace
the unit.
③Check the
head
management
sensor's
connector
connection
④If Service
mode nozzle
check pattern
printing is no
problem,
replace the
head
management
sensor unit.
Go to ★2F2F
(P3-6).
Go to ★2F2F
(P3-6).