Mitsubishi Electric 800 Series Instruction Manual (Function page 466

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Monitor value
*1
No trace data in internal RAM
0 or no display
1
Trace data in internal RAM
2
*1
The value(s) "0" to the left of the leftmost non-zero value is(are) not shown in the monitor display. For example, if no trace data is in internal RAM,
sampling retry is not performed, no trigger is detected, and trace operation is performed, "1" appears. (not "0001")
• During trace operation, the Trace status (Y40) signal can be output.
To use the Y40 signal, set "40" (positive logic) or "140" (negative logic) in one of Pr.190 to Pr.196 (Output terminal
function selection) to assign function to an output terminal.
NOTE
• Changing the terminal assignment using Pr.190 to Pr.196 (Output terminal function selection) may affect the other
functions. Set parameters after confirming the function of each terminal.
Parameters referred to
Pr.52 Operation panel main monitor
Pr.178 to Pr.189 (Input terminal function
Pr.190 to Pr.196 (Output terminal function
Fourth digit
Sampling retry not
performed
Sampling retry performed
Sampling retry count excess —
selectionpage 310
selection)page 350
selection)page 332
Trace status
Third digit
Second digit
Trigger not detected
Trigger detected
First digit
Tracing stopped
Trace operation
16. (A) Application Parameters
16.12 Trace function
11
12
13
14
15
16
17
18
19
20
465