Mitsubishi Electric 800 Series Instruction Manual (Function page 125

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

• To set individually for each quadrant, use Pr.812 Torque limit level (regeneration), Pr.813 Torque limit level (3rd
quadrant), Pr.814 Torque limit level (4th quadrant). When "9999" is set, Pr.22 setting is regarded as torque limit level
in all the quadrants.
Torque limit
Reverse
regeneration
Reverse
quad4
rotation
(Pr.814)
quad3
(Pr.813)
Reverse
driving
Rated speed
 Torque limit level using analog input (terminal 4) (Pr.810 = "1", Pr.858)
• The torque is limited with the analog input of terminal 4. (External torque limit)
• Torque limit using analog input is valid with a limit value lower than the internal torque limit (Pr.22, Pr.812 to Pr.814). (If
the torque limit using analog input exceeds the internal torque limit, the internal torque limit is valid.)
• For inputting from terminal 4, set Pr.858 Terminal 4 function assignment = "4".
• The torque limit using analog input can be calibrated by the calibration parameters C38 (Pr.932) to C41 (Pr.933). (Refer
to
page
363.)
400
150
Bias
C38(Pr.932)
0
0
C39(Pr.932)
Calibration example of terminal 4
 Internal torque limit 2 (Pr.810 = "2", Pr.805, Pr.806)
• The setting value of Pr.805 or Pr.806 is used as the torque limit value.
• When the CC-Link, CC-Link IE TSN, or CC-Link IE Field Network is used, the torque limit value can be input using a remote
register (RWwC).
Pr.804
setting
1
Torque limit by Pr.805, Pr.806
3
Torque limit by remote register (RWwC)
5
Torque limit by remote register (RWwC)
6
Torque limit by Pr.805, Pr.806
*1
The torque limit setting is defined as an absolute value.
*2
The torque limit value can also be set using the operation panel or parameter unit.
*3
The torque can also be limited by setting a value in Pr.805 or Pr.806.
*4
On the operation panel or parameter unit, the setting range is "673 to 1327 (-327% to 327%)" and the setting increment is 1%.
124
5. Speed Control
5.4 Setting the torque limit level
+
Forward
driving
Forward
quad1
(Pr.22)
rotation
Speed
quad2
(Pr.812)
Forward
regeneration
-
Gain
C40(Pr.933)
Initial value
100%
20mA
Torque setting signal
C41(Pr.933)
Torque limit input
*2
*3
*3
*2
*1
Setting range
Setting increments
600 to 1400
1%
(-400% to 400%)
-32768 to 32767 (two's
complement)
0.01%
*4
(-327.68% to 327.67%)
Required condition
FR-A8NC is installed, or CC-Link
IE TSN or CC-Link IE Field
*4
Network Basic is used.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e800 seriesFr-e800Fr-e820-0008Fr-e840-0016Fr-e860-0017Fr-e820s-0008 ... Show all