The following table explains the indications in the parameter setting mode.
Operation panel indication
Parameter setting mode
Parameter clear
All parameter clear
Fault history clear
Initial value change list
PM parameter
initialization
Automatic parameter
setting
Group parameter setting Displays parameter numbers by function groups.
2.1.3
Digital characters and their corresponding printed
equivalents
Digital characters displayed on the operation panel display are as follows.
0
D
Q
2.1.4
Changing the parameter setting value
• Select the parameter number in the parameter setting mode and press the SET key to change the parameter setting value.
• After changing the parameter setting value, press the SET key to write the setting value to the inverter.
• When the parameter number is 4-digit, "Pr." and the parameter number are displayed alternately.
• When the parameter number is 5-digit, the upper 1 digit and the lower 4 digits of the parameter number are displayed
alternately.
Function name
Under this mode, the set value of the displayed parameter number is read
or changed. If the setting is changed using a different interface while the
value is displayed, the new setting may not be applied. In such a case,
read the set value again.
Clears and resets parameter settings to the initial values. Calibration
parameters and offline auto tuning parameters are not cleared. For the
details of the uncleared parameters, refer to
Clears and resets parameter settings to the initial values. Calibration
parameters and the offline auto tuning parameters are also cleared. For
the details of the uncleared parameters, refer to
Deletes the fault history.
Identifies the parameters that have been changed from their initial
settings.
Changes the parameter settings required to drive a PM motor to the
settings for V/F control as a batch. (Not displayed for the 575 V class.)
Changes parameter settings as a batch. The target parameters include
communication parameters for the Mitsubishi Electric human machine
interface (GOT) connection and the parameters for the rated frequency
settings of 50/60 Hz.
1
2
3
4
5
E
F
G
H
I
R
S
T
U
V
Description
6
7
8
9
A
J
K
L
M
N
W
X
Y
Z
-
27
500
page
508.
500
page
508.
502
501
112
216
85
B
C
O
P
_
2. Basic Operation
2.1 Operation panel
1
Refer
to
page
2
3
4
5
6
7
8
9
10
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e800 seriesFr-e800Fr-e820-0008Fr-e840-0016Fr-e860-0017Fr-e820s-0008 ... Show all