Mitsubishi Electric 800 Series Instruction Manual (Function page 315

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

*11 The details of bits for the input terminal status are as follows. (1: ON state, 0: OFF state of a terminal on the inverter. "—" denotes an indefinite
(null) value.)
b15
Standard model
-
-
b15
Ethernet model
-
-
b15
Safety communication model
-
-
*12 The details of bits for the output terminal status are as follows. (1: ON state, 0: OFF state of a terminal on the inverter. "—" denotes an indefinite
(null) value.)
b15
Standard model
-
-
b15
Ethernet model
-
-
b15 Safety communication model
-
-
*13 The details of bits for the option input terminal status 1 are as follows. (1: ON state, 0: OFF state of a terminal on the FR-A8AX.) Every bit is 0
(OFF) when the option is not installed.
b15
X15
X14
*14 The details of bits for the option input terminal status 2 are as follows. (1: ON state, 0: OFF state of a terminal on the FR-A8AX. "—" denotes an
indefinite (null) value.) Every bit is 0 (OFF) when the option is not installed.
b15
-
-
*15 The details of bits for the option output terminal status are as follows. (1: ON state, 0: OFF state of a terminal on the FR-A8AY/A8AR. "—" denotes
an indefinite (null) value.) Every bit is 0 (OFF) when the option is not installed.
b15
-
-
*16 The increment varies depending on the Pr.53 setting. (Refer to
*17 The monitored values are retained even if an inverter fault occurs. Resetting clears the retained values.
*18 Parameter setting is not valid to set the item as the main monitor item on the LCD operation panel (FR-LU08). Use the monitor function of the
FR-LU08 for the setting.
 Monitor display for operation panel (Pr.52, Pr.774 to Pr.776)
• When Pr.52 = "0" (initial value), the monitoring of output frequency, output current, output voltage and fault display can be
selected in sequence by pressing the SET key.
• Among the items set in Pr.52, the load meter and motor load factor are displayed in the second screen (initially set to
monitor the output current). Other items are displayed in the third screen (initially set to monitor the output voltage).
• The first screen (initially set to monitor the output frequency) is displayed at power-ON in the initial setting. To change the
screen displayed at power-ON, display the screen you want to display at power-ON, and hold down the SET key for 1
second. To monitor the output frequency at power-ON again, display the screen of output frequency, and hold down the
SET key for 1 second.
Power-on monitor (first monitor)
Output frequency monitor
The following is the screen flow diagram when Pr.52 = "20" (cumulative energization time).
• Power-on monitor (first monitor)
Output frequency monitor
• The monitor item to be displayed is set using Pr.774 for the first screen, Pr.775 for the second screen, and Pr.776 for the
third screen. When Pr.774 to Pr.776 = "9999" (initial value), the Pr.52 setting value is used.
314
13. (M) Item and Output Signal for Monitoring
13.2 Monitor item selection on operation panel or via communication
-
-
-
RES
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
X13
X12
X11
X10
-
-
-
-
-
-
-
-
Second monitor
Output current monitor
• Second monitor
Output current monitor
-
-
MRS
RH
-
-
-
-
-
-
-
-
-
-
-
SO
-
-
SO
-
-
-
-
-
X9
X8
X7
X6
-
-
-
-
RA3
RA2
RA1
Y6
page
308).
Third monitor
Output voltage monitor
• Third monitor
Cumulative energization time monitor
-
-
RM
RL
-
-
-
-
-
-
-
-
-
-
ABC
FU
ABC
-
-
-
ABC
-
-
-
X5
X4
X3
X2
-
-
-
-
Y5
Y4
Y3
Y2
Fault monitor
With fault
• Fault monitor
With fault
b0
STR
STF
b0
DI1
DI0
b0
-
-
b0
-
RUN
b0
-
-
b0
-
-
b0
X1
X0
b0
-
DY
b0
Y1
Y0