Mitsubishi Electric 800 Series Instruction Manual (Function page 389

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

*2
For the settings for the SF-V5RU, refer to
*3
Set Pr.71 Applied motor according to the motor to be used and the motor constant setting range. According to the Pr.71 setting, the range of
the motor constant parameter setting values and units can be changed. (For other setting values of Pr.71, refer to
• 200/400 V class
Mitsubishi Electric high-
performance energy-
saving motor
Mitsubishi Electric high-
performance energy-
saving motor with
encoder
Mitsubishi Electric Vector
control dedicated motor
Mitsubishi Electric geared
motor
Mitsubishi Electric
inverter-driven geared
motor for encoder
feedback control
Mitsubishi Electric
standard efficiency motor
Mitsubishi Electric high-
efficiency motor
Mitsubishi Electric
constant-torque motor
Other manufacturer's
standard motor
Other manufacturer's
constant-torque motor
• 575 V class
Vector control dedicated motor
Standard motor
Constant-torque motor
Other manufacturer's standard motor
Other manufacturer's constant-torque motor
NOTE
• When Pr.11 DC injection brake operation time = "0" or Pr.12 DC injection brake operation voltage = "0", offline auto
tuning is performed at the initial setting of Pr.11 or Pr.12.
• Offline auto tuning is not performed when position control is selected (Pr.800 = "3 or 4" (when the MC signal is ON) or "5"
(when the MC signal is OFF)).
• If "wye connection" or "delta connection" is incorrectly selected in Pr.71, Advanced magnetic flux vector control, Real
sensorless vector control, and Vector control are not performed properly.
• To perform offline auto tuning for the 400 V class 0.1 kW Mitsubishi Electric geared motor (GM-[]), set "1803" in Pr.71 (Pr.450).
388
15. (C) Motor Constant Parameters
15.2 Offline auto tuning
page
405.
Motor
SF-PR
SF-PR-SC
SF-V5RU (1500 r/min series)
GM-[]
GM-DZ, GM-DP
SF-JR
SF-JR 4P 1.5 kW or lower
SF-HR
Others
SF-JRCA 4P
SF-HRCA
Others (SF-JRC, etc.)
Motor
Motor constant
parameter mH, %, and
parameter internal
A unit setting
70
73
30
33
1800
1803
0 (initial value)
3
20
23
40
43
0 (initial value)
3
10
13
50
53
10
13
0 (initial value)
3
10
13
Motor constant
parameter mH, %, and
parameter internal
A unit setting
30
33
0 (initial value)
3
10
13
0 (initial value)
3
10
13
page
380.)
Pr.71 setting
Motor constant
Motor constant
parameter Ω, mΩ, and
data setting
A unit setting
5 (wye connection
motor)
6 (delta connection
motor)
15 (wye connection
motor)
16 (delta connection
motor)
Pr.71 setting
Motor constant
Motor constant
parameter Ω, mΩ, and
data setting
A unit setting
5 (wye connection
motor)
6 (delta connection
motor)
15 (wye connection
motor)
16 (delta connection
motor)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e800 seriesFr-e800Fr-e820-0008Fr-e840-0016Fr-e860-0017Fr-e820s-0008 ... Show all

Table of Contents