Mitsubishi Electric 800 Series Instruction Manual (Function page 463

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

 Analog source (monitor item) selection
• Select the analog sources (monitor items) to be set to Pr.1027 to Pr.1034 from the following table.
Setting
Monitor item
value
1
Output frequency/speed
2
Output current
3
Output voltage
Frequency setting value/motor
5
speed setting
6
Running speed
7
Motor torque
8
Converter output voltage
9
Regenerative brake duty
Electronic thermal O/L relay load
10
factor
11
Output current peak value
Converter output voltage peak
12
value
13
Input power
14
Output power
17
Load meter
18
Motor excitation current
19
Position pulse
20
Cumulative energization time
23
Actual operation time
24
Motor load factor
32
Torque command
33
Torque current command
35
Feedback pulse
40
PLC function user monitor 1
41
PLC function user monitor 2
42
PLC function user monitor 3
52
PID set point
53
PID measured value
54
PID deviation
61
Motor thermal load factor
62
Inverter thermal load factor
64
PTC thermistor resistance
*1
"*" shows a monitor item with a high-speed sampling cycle.
*2
The monitor items with a circle (○) represents that its monitor value can be indicated with minus sign.
*3
Indicates a criterion at 100% when the analog trigger is set.
*4
Refer to the full-scale value of terminal FM or AM (on
*5
Rated motor frequency × 120 / number of motor poles
*6
When selecting the position command, current position, or droop pulse, select both upper and lower digits.
462
16. (A) Application Parameters
16.12 Trace function
Trigger
Minus (-)
*1
level
*2
display
criterion
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
*4
65535
65535
65535
*4
*4
*4
65535
*4
*4
*4
*4
*4
*4
*4
*4
Pr.561
page
Setting
Monitor item
value
*3
65
Ideal speed command
67
PID measured value 2
BACnet valid APDU counter (for
83
the FR-E800-EPA and FR-E800-
SCEPA only)
91
PID manipulated amount
97
Dancer main set speed
201
*Output frequency
202
*U-phase output current
203
*V-phase output current
204
*W-phase output current
205
Converter output voltage
206
*Output current (all three phases)
207
*Excitation current (A)
208
*Torque current (A)
209
Terminal 2
210
Terminal 4
212
*Excitation current (%)
213
*Torque current (%)
*6
*Position command (lower)
222
*6
*Position command (upper)
223
*6
*Current position (lower)
224
*6
*Current position (upper)
225
*6
*Droop pulse (lower)
226
*6
*Droop pulse (upper)
227
229
*Ideal speed command
230
*Output frequency (signed)
231
*Motor speed (with sign)
232
*Speed command (with sign)
235
*Torque command
236
*Motor torque
237
*Excitation current command
238
*Torque current command
319).
Trigger
Minus (-)
*1
level
*2
display
criterion
*4
*4
65535
*4
*4
Rated
motor
frequency
ND rated
current
ND rated
current
ND rated
current
400/800/
1000 V
ND rated
current
ND rated
current
ND rated
current
100%
100%
100%
100%
32767
32767
32767
32767
32767
32767
Rated
motor
frequency
Rated
motor
frequency
*5
*5
100%
100%
100%
100%
*3