3 Controller
<Reference> The example of connection with our PLC
<Sink>
Parallel I/O interface
Table 3-26 : Connection with a Mitsubishi PLC (Example of sink type)
<Source>
Parallel I/O interface
Table 3-27 : Connection with a Mitsubishi PLC (Example of source type)
Parallel I/O interface
3-103
(Output)
60mA
(+24/+12V)
Output
Output
24V
Fuse (24G/12G)
External
power supply
(Input)
(COM)
Input
3.3K
Input
External
power supply
(Output)
(Output)
60mA
Fuse
(+24/+12V)
Output
Output
(24G/12G)
(Input)
Input
3.3K
Input
(COM)
External
power supply
QX41
(Mitsubishi programmable
controller)
COM
X
QY41P
(Mitsubishi programmable
controller)
+24V
Y
24V
COM
24G
QX41
(Mitsubishi programmable
controller)
X
24V
COM
External
power supply
(Mitsubishi
QY81P
programmable
+24V
controller)
Y
24G
24V
*The input/output circuit external
power supply (24 VDC) must be
prepared by the customer.
Note) In the customer's system, do not
ground the + side of 24V power
supply prepared by customer for
connect to the controller.
(related with emergency stop and
parallel input/output) If it
connects with the controller
under the condition that the +
side is grounded, it will lead to
failure of controller.
*The input/output circuit external
power supply (24 VDC) must be
prepared by the customer.
Note) In the customer's system, do
not ground the + side of 24V
power supply prepared by
customer for connect to the
controller. (related with
emergency stop and parallel
input/output) If it connects
with the controller under the
condition that the + side is
grounded, it will lead to
failure of controller.