Power Switch Replacement - GE eBike III basic Series Service Manual

Electric bike with and without nibp
Table of Contents

Advertisement

p
ower swItCH replaCeMent
1. The power switch is mounted between the two rear
parts of the ergometer housing.
2. Follow the steps in
"Remove housing of the eBike III basic" on page 42
or
"Remove housing of the eBike III comfort" on page
46.
3. Remove the cables from the defect power switch and
place them on the appropriate contacts of the new
switch.
If the cable between switch and LIU board has to be
replaced, open the electronic carrier (underneath the
eBike), disconnect the power cable from the LIU board
and replace it with the spare cable included in the
package..
4. Secure the cables with a cable strap
When reassembling the housing:
5. Slide the plastic cover of the power switch in the
appropriate slot in one side part of the housing.
6. During assembly of the side parts take care, that
the plastic cover of the main switch fits into the
corresponding slot of the other side part.
- 56 -
p
ower connector
eBike III basic / comfort
(
)
liu
from main Switch
on
board
2018111-336 Rev. B