oad test protoCol
1. Perform the load test (RPM is set by the calibration device / load of the eBike III is set either by command of the test
software or manually on the eBike III -see „Manual Load" on page 66) step by step.
2. The actual load is measured and displayed by the calibration device software. Note the results in the table or use the
printed protocol of the calibration device to document the test.
Step
RPM set
#1
40
#2
40
#3
40
#4
70
#5
90
#6
100
- 16 -
Target Load
Actual Load
25
50
100
200
300
500
eBike III basic / comfort
Deviation max.
Pass / Fail
± 3 Watt
± 3 Watt
± 5 Watt
± 10 Watt
± 15 Watt
± 25 Watt