Set CLK-101 Si570 Frequency
In the Set tab, enter the desired Si570 frequency in MHz in the field next to the Set Si570 User
Frequency button and press Enter or click the button (see the following figure). After the
frequency is set, the Logging pane shows no errors and prints Finished.
Set CLK-101 Si5368 Frequency
There are two buttons in the Set tab that can be used to program the Si5368 clock source: Set
Si5368 Frequency (Auto Select) and Set Si5368 Frequency (Free Running). The free-running
option uses the onboard XA-XB crystal as the active clock routed to the Si5368 internal PLL. The
auto select option uses one of the recovery clocks routed to the SuperClock-2 Module interface
as the active clock. Enter the desired Si5368 frequency in MHz in the field next to either the
auto select or free-running buttons and press Enter or click the related button (see the following
figure). After the frequency is set, the Logging pane shows no errors and prints Finished.