Chapter 3 Specifications; Performance Specifications - Mitsubishi Electric MELSEC Q Series User Manual

Ethernet/ip network interface module for programmable controller
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

3
SPECIFICATIONS

CHAPTER 3 SPECIFICATIONS

This chapter describes the performance specifications, input/output signals, and buffer
memory of the EtherNet/IP module.
For general specifications, refer to the following manual.
3.1

Performance Specifications

The following table lists the specifications of the EtherNet/IP module.
Item
Interface
Data transmission speed
Transmission method
No. of cascade bases
Maximum node-to-node distance 200m (For one hub)
Ethernet
Maximum segment length
Connection cable
Maximum count of tags
Maximum number of characters
Class1 Tag
in a tag name
communication
Max. send/receive data size
Maximum count of tags
Class3/UCMM
Maximum number of characters
Tag
in a tag name
communication
*3
Max. send/receive data size
Number of writes to flash ROM
Number of occupied I/O points
Internal current consumption (5VDC)
External dimensions
Weight
QCPU User's Manual (Hardware Design, Maintenance and Inspection)
Table 3.1 Performance Specifications
10BASE-T
10Mbps
Base band
Check with the manufacturer of the switching hub to be used
100m (Distance between hub and node)
Cables that meet IEEE802.3 10BASE-T
standards
(Shielded twisted pair (STP) cable, or
Unshielded twisted pair (UTP) cable,
category 3(4,5))
*2
*1
256 tags
100 characters
For one tag: 722 words
*2
Total count of all tags: 32768 words
*2
*1
256 tags
100 characters
•For one tag: 252 words
*2
•Total count of all tags: 32768 words
Maximum 100000 times
32 points (I/O assignment: intelli 32points)
0.65A
98(H)
27.4(W)
0.16kg
* 1 Total of the Class1 Tag communication and the Class3/UCMM Tag communication.
* 2 The number of tags and the data size for Class1 or Class3/UCMM Tag communication can be
changed from the default value in "Common Parameter" of the "Add Own Nic" window.
(
Section 7.9.1 (1) Display and settings of the "Add Own Nic" window)
* 3 In the EtherNet/IP module, the buffer memory area used for communication data storage is
common to Class3 and UCMM Tag communications. (
* 4 This number is an overall size of a CIP data.
The maximum actual data size differs depending on the service to be executed since this is an
overall size which includes a header.
[For Tag communication]
• For write service: Maximum (241 - Number of characters in a tag name) words
Specifications
100BASE-TX
100Mbps
Cables that meet IEEE802.3 100BASE-
TX standards
(Shielded twisted pair (STP) cable,
category 5 or higher)
*5
*1
*4*5
*4
*1
90(D)[mm]
3.1 Performance Specifications
Section 3.3.1 Buffer memory list)
3
1
2
3
4
5
6
7
8
- 1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qj71eip71

Table of Contents