3.
Reinstall the focus adjustment cover.
Tightening torque for the cover should be 0.3 N • m or less.
Reference
• Focus adjustment range varies depending on models.
• LP-430(T)U / LP-420S9(T)U / LP-410(T)U: Approx. ± 3 mm
• LP-431(T)U / LP-421S9(T)U / LP-411(T)U / LP-V10U: Approx. ± 2 mm
• LP-435(T)U / LP-425S9(T)U: Approx. ± 4 mm
• LP-V15U: Approx. ± 7 mm
• LP-W052U: Approx. ± 0.7 mm
• The ruler is set to "0" at factory.
• Adjusting focus changes the marking field and spot diameter. In addition, the amount of the spot diameter difference
between the marking field center and the marking field end becomes large, which may cause uneven marking quality.
• The dual pointer is adjusted according to the distance from the work defined at the factory. When the work distance is
changed by the focus adjustment function, dual pointer does not move with this function, so it cannot be used as the
work distance guide. Refer to "Dual Pointer Function" (P.69).
ME-LP400V-OP-6